GROUP MEDICAL PRODUCTS, INC.
 Agriculture > Animal Feed >  MULTI-PARAMETER

MULTI-PARAMETER

Model Number:
AV-9000C
MULTI-PARAMETER:
PATIENT MONITOR
Power Source:
Manual
MULTI-PARAMETER
 
Detailed Description
 


MULTI-PARAMETER PATIENT MONITOR
Standard Parameters
ECG
SpO2
NIBP
Respiration
Temperature
Pulse

Feature Set
12.1 Color TFT Display with Maximum 7 Waveforms
Optional Multi-language Operation Menu
Support Patient Information Input
12-lead ECG Waveforms Display
up to 10 Minutes ECG Replay Capacity
12.1 Color TFT Display with Maximum 7 Waveforms
Two Optional Display Method: Refreshing and Rolling
Various Waveforms can be Flexibly Grouped and Changed in Color
Power Fail Safeground Function, Capable of Storing Previous Monitoring Data
Individual Digital Module Structure, Convenient for Maintenance and Upgrade
Digital SpO2 Technique, Precise Measurement for Low Perfusion and Finger Shaking
Protection Against Interference from Defibrillation and High-frequency Electrotome
Intelligent Voice/Light Alarms Accurately Transmit Diseases
Adult/Pediatric/Neonatal measurement modes
Compatible with Central Monitoring System, Support Wireless Connection

Standard Accessories
1 x ECG Cable & Wires, 1 x pack Electrodes, 1 x Adult Digital SpO2 Probe, 1 x Adult NIBP Cuff, 1 x TEMP Probe,1 x Built-in Battery, 1 x Ground Line

Optional Accessories
IBP, EtCO2, VCG, Build-in Recorder,Special Accessories for Neonatal and Pediatric Patient

Technical Specifications

HR
Measure Range: 0-250bpm
Accuracy: ±2bpm

RESP
Measure Range: 0-100%
Accuracy: ±2bpm

TEMP
Range: 25°C-45°C
Accuracy: ±0.2°C

ECG
Input: 12-lead
Lead Selection: 12-lead Automatic Shift
Sweep Speed: 25mm/s 50mm/s
Sensitivity: 5mm/mv, 10mm/v, 20mm/v

Noninvasive Blood Pressure
Measurement Technique: Automatic Oscillometric
Measurement Range:
Adult: 20-245mmHG
Pediatric: 20-135mmHG
Accuracy: ±5 mmHG
Resolution: 1 mmHG
Measure Mode: Manual/Automatic/Continuous
Range: Adult/Pediatric/Neonatal
Protection: Double Security Protection

Alarm
Range: Adjustable from Lower to Upper Limit
Cause: Irregular Indication
Indications: Audible and Visual Dual Indications

Safety
This device is designed and manufactured by strictly complying with the following standards :
CE Standard : Directive 93/42/EEC on Medical Devices.
IEC60601 Related Standards

Power Requirement
Voltage: AC100-240V 50HZ/60HZ

IBP (Optional)
Channel: Double Channel
Pressure Sensor: Sensitivity: 5V/mmHg
Pressure Name: ART, PA, CVP, RAR, LAP, ICP

CO2 (Optional)
Measure Mode: Bypass Mode
Measure Parameter: CO2 Breathe-out, Airway HR

Recorder (Optional)
Type: 50mm Thermal Recorder (Printer)
Port: Standard Parallel
Printing Setting: Manual Recording, Alarm Recording, Time Recording, Real-time Recording

Weight
4.5kg

Dimension
350x150x330mm


we are an exporter including Multi-Parameter Monitor.we can send good service for all of our customers all the world!We also accept special order about the products. If you are interested in our products. Please do not hesitate to let us know.We are pleased to give you the detailed information.We promise that we will offer you best quality and satisfying after-service.We are sincerely looking for your cooperation.


Company information:
GROUP MEDICAL PRODUCTS, INC. is an exporter of United States Other Animal Feed products.    Quality and Safety We have implemented a strict and complete quality control system, which ensures that each product can meet quality requirements of customers.    If we don't have idea of what you're looking for, please call or e-mail with your ideas and we may be able to make you something completely unique!
Hot Searches: Bleach Machine ,Industry Bleaching Machine ,Cloth Bleaching Machine ,Air Bleaching Machines ,Bleaching Machines
 